.
.
5702
Synovex One Feedlot Implant 100ct.
Zoetis - The first Trenbolone acetate implant approved for use in both feedlot steers and heifers.Â
Approximate 200 day implant
Implant Applicator sold separately!
Specially coated, sustained-release implants provide up to 200 days of increased feed efficiency and gain with one implant.
Species: Beef cattle
FEATURES / BENEFITS
First implant containing TBA and can be used in both heifers and steers.
Patented, sustained-release coating allows slow, consistent release of ingredients.
Helps increase gain up to 200 days without the need to re-implant.
SPECIFICATIONS
Contains 200 mg trenbolone acetate and 28 mg estradiol benzoate per implant.
For subcutaneous implant in steers and heifers fed in confinement for slaughter.
Do not use in veal calves, or beef or dairy replacement heifers.
INSTRUCTIONS
Step 1: Loading the SX-10 gun Â
Load the SX10 gun following the directions outlined in the instruction manual accompanying each SX10 gun. Â
Step 2: Restraint
The animal must be confined in a restraint mechanism (squeeze chute or head gate). The implant site on the back of the ear should be prepared by scrubbing with a generous-sized piece of cotton that has been soaked in a germicidal solution.
Note: If implanting horned cattle, greater safety is provided when the head is controlled by the use of a bull lead (nose tongs).
Step 3: Implant Site Â
Divide the ear into three imaginary sections as illustrated. The implanted pellets should be deposited in the center one-third of the ear as shown. To accomplish this, the SX10 gun needle should be inserted in the outer one-third of the ear as indicated by the illustration. Implanting too close to the head may cause abnormal sexual behavior. Care should be taken to avoid severing the major arteries of the ear.
Step 4: Insert Needle Â
Just before grasping the ear with one hand, release the safety by striking the butt of the gun. Holding the SX10 gun firmly with the other hand, penetrate the skin at the point shown by the illustration. Thrust the needle under the skin taking care not to penetrate the cartilage. Ease the SX10 gun forward (toward the base of the ear) until the full needle length is beneath the skin.
Step 5: Pellet Implantation Â
When the needle is completely inserted, activate the instrument by squeezing the trigger completely. Do not withdraw the needle, but allow the automatic needle retractor to release the pellets. This will allow the pellets to be deposited in a straight line in the path of the retracted needle.
Step 6: Inspection Â
Check the implant site. If properly administered, the implants should lie in a straight line under the skin .Disinfect the SX10 gun needle in a germicidal solution and re-cock the instrument by rotating the cocking grip left, pull back, rotate right, then push all the way forward. You are now ready to implant the next animal.